Fixtures need 4 updates. One after the other.
Via D3Prog / RS485/ DMX
1. Update the new Main Bootloader V1.0.0 via DMX/RS485 via D3Prog (impression-X5_1.0.0_BOOTDMX.bin)Â
2. Update the new Main Application V 1.0.1 via DMX/RS485 via D3Prog (impression-X5_1.0.1_DMX.bin)
Change the Control Protocol in the Protocol Setup Menu to iQ.Mesh:
Update via iQ.Service App:
3. Update the iQ.Mesh Version to V5.0.31
4. Update the Color Calibration to V4.5.0Â
If you have fixtures below version 0.14.5 or just an older set bootloaders:
It could occur that after the BL update (step 1) the fixture needs about 5 minutes to prepare all internal updates with its display off. Please do allow the fixture these 5 minutes before proceeding with the main update step 2, while display is off still.
The display will come back automatically during step 2.
The first two updates can be done via DMX, D3Prog, daisy chain.
When importing the bin files to a D3Prog make sure that you choose the file type „BIN“ before uploading the file to the programmer.
Please make sure that no other DMX receivers or consoles are active on the line and fixtures Control Protocol is set to DMX for step 1 and step 2 and iQ.Mesh ( iQ.Data) for step 3 and step 4. Do set to iQ.Mesh via Protocol setup menu, only!
All fixture settings will perform a reset to factory defaults after the main application update (step 2), if updateing from 0.X.X to 1.X.X
After step 4 remember to change back the Protocol Data In to DMX..