HIGHLANDER Firmware Update [Important!]
Main changes from V46 to V47
FEATURES
BUG FIXES
- Fixed: Fixtures loosing calibration data in very seldom circumstances
UPDATE PROCESS
-
1 file has to be updated via DMX/RS485:
Highlander_V47_DMX.bin
- When importing the bin file to a D3Prog make sure that you choose the file type BIN before uploading the file to the programmer.
INFO
This update is highly recommended because it solves a very rare bug where the fixtures calibration data is being lost.
DOWNLOAD
GLP Highlander Wash Firmware V47 Rev20220721-1 (zip | 537.73 KB)
impression FR10 Firmware Update
Main changes from V33 to V46
FEATURES
- Added: Subfixture Mode: Normal (default) or Independent. Set via DMX and Display Menu. When Independent the dimmer of the main module has no effect of the output of the sub modules (V34)
- Added: RDM PID: Art-Net Universe and sACN universe
- Added: RDM PID: Save fixture settings
- Modified: RDM Discovery
BUG FIXES
- Resolved: Dimmer Bug in Mode4. No output when dimmer curve is set to soft and color mix priority is set to Mix (V34)
- Resolved: Bug in Subfixture Mode Independent, submodule was not independent (V36)UPDATE PROCESS
UPDATE PROCESS
- Update with D3Prog, only, Version 42 or higher / PC software Version 605 or higher, daisy chain via RS485/DMX
- Change filetype to Bin before you load the file with the PC software and make sure fixtures are running in DMX Mode.
- Make sure no other DMX controllers or responders are active.
INFO
The update is show critical as some bugs were solved affecting the fixtures output.
DOWNLOAD
GLP impression FR10 Bar Firmware V46 Rev20220721-1 (zip | 463.3 KB)
JDC-Line Firmware Update
Main changes from V0.6.7 to V0.6.9
FEATURES
- Added: Subfixture Mode: Normal (default) or Independent. Set via DMX and Display Menu. When Independent the dimmer of the main module has no effect of the output of the sub modules (V34)
- Added: RDM PID: Art-Net Universe and sACN universe
- Added: RDM PID: Save fixture settings
- Modified: RDM Discovery
BUG FIXES
- Resolved: Dimmer Bug in Mode4. No output when dimmer curve is set to soft and color mix priority is set to Mix (V34)
- Resolved: Bug in Subfixture Mode Independent, submodule was not independent (V36)
UPDATE PROCESS
- Update with D3Prog, only, Version 42 or higher / PC software Version 605 or higher, daisy chain via RS485/DMX
- Change filetype to Bin before you load the file with the PC software and make sure fixtures are running in DMX Mode.
- Make sure no other DMX controllers or responders are active.
INFO
The update is show critical as some bugs were solved affecting the fixtures output.
DOWNLOAD
GLP JDC Line 500 1000 Firmware V0-6-9 Rev20220722-1 (zip | 686.82 KB)
|